BackPrint
TSP: 
TSP Name: 
Critical Notice Description: 
Notice Effective Date: 
Notice Effective Time: 
Notice End Date: 
Notice End Time: 
Notice Identifier: 
Notice Status Description: 
Notice Type: 
Posting Date: 
Posting Time: 
Prior Notice Identifier: 
Required Response
  Indicator Description: 
Response Date: 
Response Time: 
Subject: 
007932908
Texas Eastern Transmission, LP
Critical notice
09/05/2019
09:00:00 AM
09/06/2019
09:00:00 AM
88203
Initiate
Capacity Constraint
09/04/2019
03:26:59 PM


No response required


TE Pipeline Conditions for 9/5/2019


Notice Text:


For Gas Day September 5, 2019, Texas Eastern (TE) has approved and scheduled nominations at each pipeline segment and meter station up to TE's operational capacity. The following locations have been restricted due to requested nominations exceeding TE's operational capacity:

Due to the ongoing Force Majeure, until further notice, TE has restricted interruptible, secondary out of path, secondary in path and a portion of primary firm nominations sourced either in the M1-24", M2-24", M2-30" north of Danville Compressor Station (Danville) or in M3 for delivery south of Danville. No increases for receipt nominations sourced either in the M1-24", M2-24", M2-30" north of Danville or in M3 for delivery south of Danville will be accepted.

TE has restricted interruptible and secondary out of path nominations that exceed entitlements sourced either on the M1-24", M2-24", M2-30" north of Berne Compressor Station (Berne) or in M3 for delivery south of Berne. No increases for receipt nominations sourced either in the M1-24", M2-24", M2-30" north of Berne or in M3 for delivery south of Berne will be accepted.

TE has restricted interruptible and secondary out of path nominations that exceed entitlements sourced either in the M1-24", M2-24", M1-30" north of Barton Compressor Station (Barton), M2-30" or in M3 for delivery south of Barton. No increases for receipt nominations sourced either in the M1-24", M2-24", M1-30" north of Barton, M2-30" or in M3 for delivery south of Barton will be accepted.

TE has restricted and sealed nominations on TE's lease capacity with Algonquin Gas Transmission (AGT) to TE's Maximum Daily Quantity (MDQ).

TE has restricted TABS, interruptible and a portion of secondary out of path nominations that exceed entitlements sourced from points east of Lambertville for delivery to points west of Lambertville. No increases for receipt nominations sourced from points east of Lambertville for delivery to points west of Lambertville will be accepted.

TE has restricted interruptible and a portion of secondary out of path nominations that exceed entitlements sourced upstream of Chester Junction Line 1A for delivery downstream of Chester Junction Line 1A on the Philadelphia Lateral. No increases in deliveries sourced upstream of Chester Junction Line 1A for delivery downstream of Chester Junction Line 1A will be accepted except for Firm No-Notice services.

TE has restricted interruptible, secondary out of path and a portion of secondary within path delivery nominations to meter 75919 (TRANSCO - BELLE MEADE, NJ). No increases in delivery nominations to meter 75919 will be accepted.

TE has restricted interruptible and a portion of secondary out of path nominations that exceed entitlements sourced in STX, WLA, ELA, M1-30", M2-30", M3 and receipt points north of Lebanon on the M2-24 for delivery south of Lebanon to the M1-24", M2-24" or delivery locations in ETX between Longview and N. Little Rock. No increases in receipts sourced in STX, WLA, ELA, M1- 30", M2-30", M3 and receipt points north of Lebanon on the M2-24 for delivery to the M1-24", M2-24" or delivery locations in ETX between LGV and N. Little Rock will be accepted.

TE has restricted interruptible and secondary out of path nominations that exceed entitlements sourced in ETX for delivery in STX, WLA, or ELA. No increases in receipt nominations sourced in ETX for delivery in STX, WLA or ELA will be accepted.

As previously posted, due to the unplanned outage on line 41-A in the Cameron System, the following meters will be unavailable for flow:

72135 - MARATHON - VER(S) 369-A, LA
73646 - ARENA OFFSHORE, LP -EC 328
73696 - GOMEX VR 282

TE has Force Balanced a portion of short TABS pools in Access Area zones ETX, STX, ELA and WLA and Market Area zones M1-24, M1-30, M2-24 and M2-30 and will continue to throughout subsequent nomination cycles.

TE has Force Balanced a portion of long TABS pools in Access Area zones STX, ETX and ELA and Market Area zones M1-24, M2-24, M2-30 and M3 and will continue to throughout subsequent nomination cycles.

TE requires all shippers and point operators in Market Area Zones M2-30" and M-3 to carefully review demand for gas and schedule gas consistent with daily needs and to tender and receive gas consistent with confirmed nominations regardless of their cumulative imbalance position unless otherwise coordinated with your operations account representative.

Additionally, TE requires all delivery point operators in Market Area Zone M1-30 to keep actual daily takes out of the system equal to or greater than scheduled quantities regardless of their cumulative imbalance position unless otherwise coordinated with your operations account representative. All receipt point operators in Market Area Zone M1-30 are required to keep actual daily receipts into the system equal to or less than scheduled quantities regardless of their cumulative imbalance position unless otherwise coordinated with your operations account representative.

Furthermore, TE requires all delivery point operators Access Area Zones STX, ETX, WLA and ELA and Market Area Zones M1-24" and M2-24" to keep actual daily takes out of the system equal to or less than scheduled quantities regardless of their cumulative imbalance position unless otherwise coordinated with your operations account representative. All receipt point operators in Access Area Zones STX, ETX, WLA and ELA and Market Area Zones M1- 24" and M2-24" are required to keep actual daily receipts into the system equal to or greater than scheduled quantities regardless of their cumulative imbalance position unless otherwise coordinated with your operations account representative.

Please contact your Operations Account Representative should you have any questions.